This instruction manual is written for users of the TI-RCP Remote Control Pad. To ensure correct usage, read this manual carefully before operating the product. No part of this manual may be reproduced or transmitted in any form without prior written permission from Nikon. The contents of this manual are subject to change without notice. This application is used to make settings for the Inverted Research Microscope ECLIPSE Ti2-E/Ti2-A, control the Ti2-E, display the Ti2-A status, and display the Assist Guide. Supported Microscopes - Nikon ECLIPSE Ti2-E (FW 1.41 or later) - Nikon ECLIPSE Ti2-A (FW 1.20 or later) Supported OS - Android 5.1 or later - There is no guarantee that this application will run on all Android devices. May 07, 2018 Nikon Eclipse Ti-S Microscope 4x 10x 20x Brightfield, Phase Contrast, Fluorescence - 10271 - Duration: 1:41. WWW.BOSTONIND.COM Laboratory & Scientific Lab Equipment Boston Industries, Inc.
- Nikon Eclipse Ti Microscope Manual
- Eclipse Ti Subwoofer
- Nikon E400 Microscope Manual Pdf
- Nikon Eclipse Ti Manual Pdf
- Nikon Eclipse Ts100 Manual
- Nikon Eclipse Ti Manual Pdf
Nikon’s basic inverted microscope with two built-in imaging ports that can be dedicated to specific tasks.
Entry-level research grade inverted microscope with excellent cost-to-performance
The Eclipse Ti-S Inverted Research Microscope is Nikon’s entry level research microscope with the basic model offering two built-in imaging ports that can be dedicated to specific tasks. This microscope is an excellent starting building block for many research applications. The Eclipse Ti-S uses Nikon’s world-famous CFI60optical system and a wide choice of objectives for bright field, dark field, fluorescence, phase contrast, DIC and modulation contrast microscopy techniques.
The Eclipse Ti-S Inverted Research Microscope is Nikon’s entry level research microscope with the basic model offering two built-in imaging ports that can be dedicated to specific tasks. This microscope is an excellent starting building block for many research applications. The Eclipse Ti-S uses Nikon’s world-famous CFI60optical system and a wide choice of objectives for bright field, dark field, fluorescence, phase contrast, DIC and modulation contrast microscopy techniques.
High-speed Motorized Control and AcquisitionThe operational speeds of motorized components such as the nosepiece, fluorescence filters and stage have been greatly enhanced, allowing high-speed screening image capture during multi-dimensional experiments. Faster device movement and image acquisition reduce overall light exposure and subsequent photo-toxicity, leading to more meaningful data. The digital Controller Hub significantly increases motorized accessory speed by reducing communication overhead time between components, boosting total operation speed.
Multipoint snapshots of HeLa cells transiently expressing Venus-tubulin and mCherry-actin and stained with Hoechst33342 and DiD. (All in pseudo-color) Dr. Kenta Saito, Research Institute for Electronic Science, Hokkaido University and Dr. Takeharu Nagai, The Institute of Scientific and Industrial Research, Osaka University
High-quality Phase Contrast Images using High NA Lenses
The revolutionary external phase contrast unit enables the use of high N.A. non-phase contrast objective lenses for phase contrast imaging by the use of an external phase ring. As this external phase ring is not in the epi-fluorescence light path, users can capture both fluorescence images as well as phase contrast images without compromising on fluorescence tranmission.
Advanced Integration with Peripherals via NIS-Elements Imaging Software
Nikon’s comprehensive imaging software NIS-Elements provides an integrated control of the microscope, cameras, components and peripherals. The intuitive GUI and efficient workflow make the programming of automated imaging sequences up to 6D (X, Y, Z, time, wavelength, multipoint) easy to perform. Ark vpn free for mac book.
Two-tiered Configuration Capability
Taking advantage of the Nikon Ti’s stratum structure, modules can be incorporated as two separate layers with multiple modules per layer. Using a dual layer configuration enables optimal filter configuration for each illumination module. This enables optimal filter selection and improves experimental accuracy whilst maintaining the highest acquisition speeds.
Multiport Design with a Maximum of Five Imaging Ports
The Ti-U has two built-in imaging ports* that can be dedicated to specific tasks, offering a flexible configuration at a high cost-to-performance ratio.
(* With Ti-U/B model with bottom port) Pes 2002 free for pc.
The Ti-U has two built-in imaging ports* that can be dedicated to specific tasks, offering a flexible configuration at a high cost-to-performance ratio.
(* With Ti-U/B model with bottom port) Pes 2002 free for pc.
Main body | Port | Ti-S: 2 portsEyepiece 100%, eyepiece 20%/left 80%***Ti-S/L100: 2 portsEyepiece 100%, left 100%***Manual optical path switching |
---|---|---|
Two ports (tube base unit with side port, back port) can be added optionally | ||
Focusing | Via nosepiece up/down movementStroke (manual): up 8mm, down 3mmCoarse stroke: 5.0mm/rotationFine stroke: 0.1mm/rotationMinimum fine reading: 1µm | |
-- | ||
Intermediate magnification | -- | |
Other | -- | |
Eyepiece tube | Eyepiece tube body | TI-TD Binocular Tube D, TI-TS Binocular Tube S, TI-TERG Ergonomic Tube |
Eyepiece tube base | TI-T-B Eyepiece Tube Base Unit, TI-T-BPH Eyepiece Tube Base Unit for PH, TI-T-BS Eyepiece Tube Base Unit with Side Port | |
Eyepiece lens | CFI 10x, 12.5x, 15x | |
Illumination pillar | TI-DS Diascopic Illumination Pillar 30W, TI-DH Diascopic Illumination Pillar 100W | |
Condenser | ELWD condenser, LWD condenser, NAMC condenser, ELWD-S condenser, High NA condenser, Darkfield condenser, CLWD condenser | |
Nosepiece | -- | |
TI-ND6-E Motorized Sextuple DIC Nosepiece, TI-N6 Sextuple Nosepiece, TI-ND6 Sextuple DIC Nosepiece | ||
Objectives | CFI60 objectives | |
Stage | TI-S-ER Motorized Stage with Encoders, TI-S-E Motorized Stage—Cross travel: X110 × Y75 mm, Size: W400 × D300 mm (except extrusions)TI-SR Rectangular Mechanical Stage, TI-SR/F Rectangular Stage with front positioned knob, TI-SSR Short-handle Rectangular Stage-Cross travel: X70 x Y50mm, Size: W310 x D300mmTI-SP Plain Stage—Size: W260 x D300 mmTI-SAM Attachable Mechanical Stage—Cross travel: X126 × Y84 mm when used with TI-SP Plain Stage | |
Motorized functions | ― | |
Epi-fluorescence attachment | Sextuple fluorescence filter cube rotating turret, Filter cubes with noise terminator mechanism, Field diaphragm centerable, 33mm ND4/ND8 filters, 25mm heat absorbing filterOption: Motorized sextuple fluorescence filter cube rotating turret, Motorized excitation filter wheel, Motorized barrier filter wheel | |
Nomarski DIC system | Contrast control: Senarmont method (by rotating polarizer)Objective side prism: for individual objectives (installed in nosepiece)Condenser side prism: LWD N1/N2/NR (Dry), HNA N2/NR (Dry/Oil) types | |
Weight (approx.) | Phase contrast set: 29.6kgEpi-fl set: 33.4kg | |
Power consumption (max.) | Full set (with HUB-A-U and peripherals): approx. 40W |
![Eclipse Eclipse](https://www.csi.nus.edu.sg/web/wp-content/uploads/2018/04/nikon-eclipse.jpg)
Reservation System:Nikon Eclipse Ti2-E
Location: BioCity, 5th floor, room 5149
2x Nikon Plan-Apochromat
• Numerical Aperture: 0.06
• Working Distance: 7.5 mm
• Immersion: Without immersion
10x Nikon CFI Plan-Fluor
• Numerical Aperture: 0.3
• Working Distance: 15.2 mm
• Immersion: Without immersion
20x Nikon CFI S Plan Fluor ELWD
• Numerical Aperture: 0.45
• Working Distance: 8.2-6.9 mm
• Immersion: Without immersion
20x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 0.75
• Working Distance: 1 mm
• Immersion: Without immersion
• Numerical Aperture: 0.06
• Working Distance: 7.5 mm
• Immersion: Without immersion
10x Nikon CFI Plan-Fluor
• Numerical Aperture: 0.3
• Working Distance: 15.2 mm
• Immersion: Without immersion
20x Nikon CFI S Plan Fluor ELWD
• Numerical Aperture: 0.45
• Working Distance: 8.2-6.9 mm
• Immersion: Without immersion
20x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 0.75
• Working Distance: 1 mm
• Immersion: Without immersion
Nikon Eclipse Ti Microscope Manual
40x Nikon CFI S Plan Fluor ELWD ADM
• Numerical Aperture: 0.6
• Working Distance: 3.6-2.8 mm
• Immersion: Without immersion
60x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 1.4
• Working Distance: 0.13 mm
• Immersion: Oil
100x Nikon Apo TIRF
• Numerical Aperture: 1.49
• Working Distance: 0.12 mm
• Immersion: Oil
The Nikon Ti2-E uses Lumencor Spectra X LED excitation.• Numerical Aperture: 0.6
• Working Distance: 3.6-2.8 mm
• Immersion: Without immersion
60x Nikon CFI Plan Apo Lambda
• Numerical Aperture: 1.4
• Working Distance: 0.13 mm
• Immersion: Oil
100x Nikon Apo TIRF
• Numerical Aperture: 1.49
• Working Distance: 0.12 mm
• Immersion: Oil
- 395nm
- 440nm
- 470nm
- 575nm
- 640nm
- 740nm
Eclipse Ti Subwoofer
- 86006 – CFP/YFP/DsRed
- 84000v2 – DAPI/ FITC/TRITC/Cy5
- 86012v2 – DAPI/FITC/TxRed/Cy5
- 96377 – Cy7-B
- DIC
Orca Emission filters
- DAPI sPx 435/26nm
- CFP 475/20nm
- GFP sPx 515/30nm
- YFP 540/21nm
- DAPI
- CFP
- GFP
- YFP
- TexasRed
- mCherry 632/60nm
- Cy5 sPx 705/71nm
- Cy7 sPx 809/81nm
2048 x 2048 pixelsNikonDS-Fi3 CMOS (colour)
Nikon E400 Microscope Manual Pdf
2880 x 2048 pixelsNikon Eclipse Ti Manual Pdf
NIS-Elements AR 5.11.00 64-bit NIS-Elements viewerNikon Eclipse Ts100 Manual
Nikon Eclipse Ti Manual Pdf
- Nikon Perfect focus system
- Environment chamber - Okolab
- Temperature control - Okolab